• Novai

    Recloser Eaton Nova

    This specification describes the features and ratings of the NOVA recloser. The NOVA recloser shall be a three-phase electronically controlled recloser suitable for pole or substation mounting. It shall utilize shatter-resistant outdoor cycloaliphatic epoxy encapsulated axial-field vacuum interrupters. Current sensing shall be provided by three internally encapsulated current transformers. The NOVA recloser shall be available with optional Internal Voltage Sensing. The Form 6 or Form 4D electronic control, coupled with the NOVA recloser, constitutes the NOVA recloser system.

    • The Quality Management System shall be ISO 9001 Certified.

    The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

    IEEE Std C37.60™-2003 standard – IEEE Standard Requirements for Overhead, Pad-Mounted, Dry Vault and Submersible Automatic Circuit Reclosers and Fault Interrupters for Alternating Current Systems

    ANSI C37.61-1973/IEEE Std 321™-1973 standard – IEEE Standard Guide for the Application, Operation, and Maintenance of Automatic Circuit Reclosers. 

    ANSI C37.85-2002 – American National Standard Safety Requirements for X-Radiation Limits for AC High-Voltage Power Switchgear.

  • AN01813_Cover_2.indd

    Residual Current Protective Devices – RCCB

    RCCB

    • Standards: IEC/EN 61008-1 (VDE 0664-10) , IEC 61008-2-1 (VDE 0664-11), IEC/EN 61009-1 , IEC/EN 61009-2-1 , IEC/EN 61543 (VDE 0664-20,21,30)
    • Rated current in up to 63A
    • Rated voltage Un: 230/400V AC
    • Leakage current up to 500mA
  • Picture7

    RMU Xiria 24kV

     

    Specification:

    Rated Voltage up to 24kV

    Rated Current up to 630A

    Rated Short circuit withstand current up to 20kA/3s

    Internal Arc Current 20 kA

    Internal Arc Class (IAC) AFLR

    Loss of service continuity: LSC Class LSB2B

    Partition class: PM

  • 2

    RVAC- Ring main Unit

    Eaton RVAC Series Complete SF6 Gas Insulated Metal Enclosed Modular and Compact Switchgears (RMU) with its increased functional properties and minimized dimensions can be used in today’s advanced MV secondary distribution systems.

    • Rated 40,5 kV.
    • Up to 25kA.
    • Up to 630 A.
    • Single busbar.
    • Type-tested.
    • Metal-enclosed.
    • Climate independent.
    • Maintenance-free.
    • Individual panels and block versions.
    • No gas work at site.
    • Fast and easy to install.
  • 2

    SIMOSEC

    Air-insulated switchgear for secondary distribution systems

    • Rate voltage: 24 kV
    • Rated lightning impulse withstand voltage : 125 kV
    • Rated short-duration power-frequency withstand voltage: 60 kV
    • Rated frequency: 50/60 Hz
    • Internal arc class: IAC -AFLR
    • LSC: LSC2B
    • Busbar: 630A, 800A, 1250A
    • Rated normal current for feeders: 630A
    • Rated short-time withstand current: 25kA/s
    • Rated short-circuit breaking current: 25kA
    • Rated peak withstand current: 62,5kA
    • Metal-enclosed.
    • Single busbar.
    • Air-insulated technology combined with a gas-insulated switching function.
    • Factory-assembled, type-tested switchgear according to IEC 62271-200

     

  • emergencystop-siemens

    Switch Disconnectors

    Switch Disconnectors: 

    • Standard: IEC 60947
    • Rated operational voltage Ue: 690V AC
    • Switch Disconnectors up to 1600A
    • Switch Disconnectors with fuses up to 800A
    • Fuse Switch Disconnectors up to 2000A
  • AN01813_Cover_2.indd

    Switching Devices

    Switching Devices:

    • Standard: IEC 60947 , IEC 60669
    • Rated operational voltage Ue: 230/400V AC
    • Rated operational current Iup to : 63 A
  • Banner 2-2

    TMC Transformers

    Type: Dry type transformer
    – Standard: IEC 60076-11.
    – Type of installation: indoor and our door (with enclosure IP)
    – Frequency: 50Hz (60Hz)
    – Phase: 3 phases.
    – Capacity: up to 52 MVA
    – Primary rated voltage: 35kV; 22kV; 15kV; uo to 25kV
    – Secondary rated voltage: 0.4kV;6kV; 11kV (on request)
    – Off-Load Tapping on HV Coil : ±2×2,5% (on request)
    – Vector Group: Dyn 11 (on request)
    – Type of cooling: AN hay AN/AF, AFWF, AFAF, WF
    – Insulation Class (HV/LV): F/F, H/H
    – Average Winding Temp. Rise (HV/LV:100/100 (K)
    – Winding Material (HV/LV): AL or Cu.
    – Ambient Condition ( Max/ Min/Yearly average/Daily): 40/-25/20/30oC (C2).
    – Altitude: ≤ 1000 m
    – Environmental Class: E2
    – Fire Behavior Class:F1
    – Climatic Class: C2

  • AN01813_Cover_2.indd

    Transformers, Bells and Socket Outlets

    Transformers, Power Supply Units and Socket Outlet

    • Standard: IEC 61558
    • Rated operational voltage Ue: 230V AC
    • 4AC3 bell transformers up to 18 VA
    • 4AC3 safety transformers up to 63 VA
    • 4AC2 power supply units up to 8.4 W
    • 5TE6 REG socket outlets up to 16 A
  • Uring

    URING (RMU)

    URING Series Complete SF6 Gas Insulated Metal Enclosed Modular and Compact Switchgears (RMU) with its increased functional properties and minimized dimensions can be used in today’s advanced MV secondary distribution systems.

    The RMUs suitable to use in SCADA systems are operated with Puffer system (directing the SF6 gas directly on the arc). RMU offer a unique solution to the user with its remote opening closing property even without the motor provided that the mechanism is installed previously. The RMU offer smart solutions to the user due to their compact dimensions and increased safety properties in a metal or concrete kiosk type substation in the MV secondary distribution systems.

    • Rated 36 kV.
    • Up to 21kA.
    • Up to 630 A.
    • Single busbar.
    • Type-tested.
    • Metal-enclosed.
    • Climate independent.
    • Maintenance-free.
    • Individual panels and block versions.
    • No gas work at site.
    • Fast and easy to install.