LOW VOLTAGE PRODUCTS

  • AN01813_Cover_2.indd

    Air Circuit Breakers – ACB

    3WL Air circuit breaker for system protection

    • 3 sizes : I, II, III
    • Rated current in up to 6300A
    • Rated operational voltage Ue: 690/1000/1150 V
    • Rated ultimate short-circuit breaking capacity at 500 V AC up to 150kA
    • Fixed mounted and Draw-out type.
    • Protection relay and intelligent communication integrated
  • AN01813_Cover_2.indd

    Fuse Systems

  • AN01813_Cover_2.indd

    Measuring Devices and Power Management

    Measuring Devices and Power Monitoring: 

    • Standard: IEC 61557 , IEC 60255
    • Rated operational voltage Ue: 230V AC
    • Values: U,I,S,P,Q,LF…
    • 5TE6 REG socket outlets up to 16 A
  • AN01813_Cover_2.indd

    Miniature Circuit Breakers – MCB

    MCB

    • Standards: IEC/EN 60898 , EN 60947-2
    • Rated current in up to 125A
    • Rated voltage Un: 230/400V AC
    • Icu up to 15kA
    • Functions: Overloads and Short-circuits protection
    • Additional components can be retrofitted individually
  • AN01813_Cover_2.indd

    Molded Case Circuit Breakers – MCCB

    MCCB-3VT

    • Standard: IEC/EN 60947-2
    • Rated current in up to 1600A
    • Rated operational voltage Ue: 690V
    • Rated ultimate short-circuit breaking capacity at 415 V up to 65 kA

    MCCB-SENTRON 3VL

    • Standard: IEC/EN 60947-1 , IEC/EN 60947-2 , DIN VDE 0660-100&101
    • Rated current in up to 1600A
    • Rated operational voltage U: 415/440/690V AC
    • Rated ultimate short-circuit breaking capacity up to 100 kA
    • Mounting type: Fixed, withdrawable, plug-in
    • Comunication intergrated
  • AN01813_Cover_2.indd

    Monitoring Devices

    Monitoring Devices:

    • Standard: IEC 60947 , IEC 60255
    • Transfer switches
    • Monitoring devices for electrical values
    • Monitoring devices for plants and devices
    • Charging infrastructure for electric vehicles
  • AN01813_Cover_2.indd

    Overvoltage Protection Devices

    Lightning arresters: Overvoltage Protection Devices

    • Standard: IEC 61643-11
    • Rated voltage Un: 240/415V AC
    • Lightning impulse current up to: 75/100 kA
    • Protection level up to: 5kV
  • AN01813_Cover_2.indd

    Residual Current Protective Devices – RCCB

    RCCB

    • Standards: IEC/EN 61008-1 (VDE 0664-10) , IEC 61008-2-1 (VDE 0664-11), IEC/EN 61009-1 , IEC/EN 61009-2-1 , IEC/EN 61543 (VDE 0664-20,21,30)
    • Rated current in up to 63A
    • Rated voltage Un: 230/400V AC
    • Leakage current up to 500mA
  • emergencystop-siemens

    Switch Disconnectors

    Switch Disconnectors: 

    • Standard: IEC 60947
    • Rated operational voltage Ue: 690V AC
    • Switch Disconnectors up to 1600A
    • Switch Disconnectors with fuses up to 800A
    • Fuse Switch Disconnectors up to 2000A
  • AN01813_Cover_2.indd

    Switching Devices

    Switching Devices:

    • Standard: IEC 60947 , IEC 60669
    • Rated operational voltage Ue: 230/400V AC
    • Rated operational current Iup to : 63 A
  • AN01813_Cover_2.indd

    Transformers, Bells and Socket Outlets

    Transformers, Power Supply Units and Socket Outlet

    • Standard: IEC 61558
    • Rated operational voltage Ue: 230V AC
    • 4AC3 bell transformers up to 18 VA
    • 4AC3 safety transformers up to 63 VA
    • 4AC2 power supply units up to 8.4 W
    • 5TE6 REG socket outlets up to 16 A