• 8djh-1

    8DJH

    Gas-insulated switchgear for secondary distribution systems

    • Up to 24 kV
    • Up to 25 kA(17,5kV) and  20kA ở 24kV
    • Up to 630 A
    • Metal-enclosed
    • Climate-independent
    • Maintenance-free
    • Individual panels and block versions
    • No gas work at site
    • Fast and easy to install

     

  • AN01813_Cover_2.indd

    Air Circuit Breakers – ACB

    3WL Air circuit breaker for system protection

    • 3 sizes : I, II, III
    • Rated current in up to 6300A
    • Rated operational voltage Ue: 690/1000/1150 V
    • Rated ultimate short-circuit breaking capacity at 500 V AC up to 150kA
    • Fixed mounted and Draw-out type.
    • Protection relay and intelligent communication integrated
  • LBS-1

    Cooper NOVAs SF6 Load Break Switch (LBS)

    1. Rated voltage: 24kV
    2.Rated power-frequency withstand voltage 50Hz 1Min (kV r.m.s.):
    – To earth and between phase: 50kV
    – Across the isolating distance: 60 kV
    3.Rated lightning impulse withstand voltage (peak value):
    – To earth and between phase: 125kV
    – Across the isolating distance: 145kV
    4.Rated current: 630A
    5.Short-time withstand current: 20kA/3s
    6.Peak value: 50kA

  • Picture1

    Eaton Dry Type Transformer

    • Type: Cast Resin Dry
    • Standard: IEC 60076-11.
    • Installation: Indoor, Outdoor
    • Rated frequency: 50Hz (60Hz)
    • Rated phase: 3 phase.
    • Rated capacity: from 200kVA to 31.5MVA
    • Rated HV: 35kV; 22kV; 15kV; up to 110kV
    • Rated LV: 0.4kV;6kV; 11kV 
    • HV tapping: ±2×2,5% 
    • Vector group: Dyn 11 
    • Cooling method: AN or AN/AF
    • Insulation class (HV/LV): F/F.
    • Average temperature rise (HV/LV: 100/100 (K)
    • Winding material (HV/LV): Aluminum hay Copper.
    • Ambient Temp (Max. / Min. / Year / day): 40/-25/20/30oC (C2)..
    • Altitude: ≤ 1000 m
    • Environmental class: E3
    • Fire resistance class:F1
    • Climate category: C3
  • AN01813_Cover_2.indd

    Fuse Systems

  • 170405-geafol-neo-2

    GEAFOL Neo

    • Type: Cast Resin Dry
    • Standard: IEC 60076-11.
    • Installation: Indoor, Outdoor
    • Rated frequency: 50Hz (60Hz)
    • Rated phase: 3 phase.
    • Rated capacity: from 200kVA to 50MVA
    • Rated HV: 35kV; 22kV; 15kV; up to 52kV
    • Rated LV: 0.4kV;6kV; 11kV 
    • HV tapping: ±2×2,5% 
    • Vector group: Dyn 11 
    • Cooling method: AN or AN/AF
    • Insulation class (HV/LV): F/F.
    • Average temperature rise (HV/LV: 100/100 (K)
    • Winding material (HV/LV): Aluminum hay Copper.
    • Ambient Temp (Max. / Min. / Year / day): 40/-25/20/30oC (C2)..
    • Altitude: ≤ 1000 m
    • Environmental class: E2
    • Fire resistance class:F1
    • Climate category: C2
  • AN01813_Cover_2.indd

    Measuring Devices and Power Management

    Measuring Devices and Power Monitoring: 

    • Standard: IEC 61557 , IEC 60255
    • Rated operational voltage Ue: 230V AC
    • Values: U,I,S,P,Q,LF…
    • 5TE6 REG socket outlets up to 16 A
  • AN01813_Cover_2.indd

    Miniature Circuit Breakers – MCB

    MCB

    • Standards: IEC/EN 60898 , EN 60947-2
    • Rated current in up to 125A
    • Rated voltage Un: 230/400V AC
    • Icu up to 15kA
    • Functions: Overloads and Short-circuits protection
    • Additional components can be retrofitted individually
  • AN01813_Cover_2.indd

    Molded Case Circuit Breakers – MCCB

    MCCB-3VT

    • Standard: IEC/EN 60947-2
    • Rated current in up to 1600A
    • Rated operational voltage Ue: 690V
    • Rated ultimate short-circuit breaking capacity at 415 V up to 65 kA

    MCCB-SENTRON 3VL

    • Standard: IEC/EN 60947-1 , IEC/EN 60947-2 , DIN VDE 0660-100&101
    • Rated current in up to 1600A
    • Rated operational voltage U: 415/440/690V AC
    • Rated ultimate short-circuit breaking capacity up to 100 kA
    • Mounting type: Fixed, withdrawable, plug-in
    • Comunication intergrated
  • AN01813_Cover_2.indd

    Monitoring Devices

    Monitoring Devices:

    • Standard: IEC 60947 , IEC 60255
    • Transfer switches
    • Monitoring devices for electrical values
    • Monitoring devices for plants and devices
    • Charging infrastructure for electric vehicles
  • AN01813_Cover_2.indd

    Overvoltage Protection Devices

    Lightning arresters: Overvoltage Protection Devices

    • Standard: IEC 61643-11
    • Rated voltage Un: 240/415V AC
    • Lightning impulse current up to: 75/100 kA
    • Protection level up to: 5kV
  • Image converted using ifftoany

    Power Xpert UX

    • Up to 24kV, 36 kV, 25 kA/3s, 2500 A busbar, 2500 A feeder
    • Impulse withstand voltage: 125kV
    • Power frequency withstand voltage: 50kV
    • Rated frequency: 50/60 Hz.
    • Metal-Clad design.
    • Single-busbar System
    • Air-insulated and Solid insulated system
    • Rated short-time withstands current, 25kA/ 3s, 31.5kA/3s
    • Internal arc classification AFLR up to 31.5kA
    • Degree of protection: IP4X (IP41, IP42 or IP44 as an option)
    • Loss of service continuity category: LSC2B
    • Partition class: PM
    • Standard color: RAL 7035
    • Rack-in, rack-out operations of the circuit-breaker truck with the high-voltage door closed.
    • Factory-assembled, type-tested switchgear according to IEC 62 271-200.
    • Interlocking between high-voltage door and switching device.