• 8djh-1

    8DJH

    Gas-insulated switchgear for secondary distribution systems

    • Up to 24 kV
    • Up to 25 kA(17,5kV) and  20kA ở 24kV
    • Up to 630 A
    • Metal-enclosed
    • Climate-independent
    • Maintenance-free
    • Individual panels and block versions
    • No gas work at site
    • Fast and easy to install

     

  • AN01813_Cover_2.indd

    Air Circuit Breakers – ACB

    3WL Air circuit breaker for system protection

    • 3 sizes : I, II, III
    • Rated current in up to 6300A
    • Rated operational voltage Ue: 690/1000/1150 V
    • Rated ultimate short-circuit breaking capacity at 500 V AC up to 150kA
    • Fixed mounted and Draw-out type.
    • Protection relay and intelligent communication integrated
  • AN01813_Cover_2.indd

    Fuse Systems

  • 170405-geafol-neo-2

    GEAFOL Neo

    • Type: Cast Resin Dry
    • Standard: IEC 60076-11.
    • Installation: Indoor, Outdoor
    • Rated frequency: 50Hz (60Hz)
    • Rated phase: 3 phase.
    • Rated capacity: from 200kVA to 50MVA
    • Rated HV: 35kV; 22kV; 15kV; up to 52kV
    • Rated LV: 0.4kV;6kV; 11kV 
    • HV tapping: ±2×2,5% 
    • Vector group: Dyn 11 
    • Cooling method: AN or AN/AF
    • Insulation class (HV/LV): F/F.
    • Average temperature rise (HV/LV: 100/100 (K)
    • Winding material (HV/LV): Aluminum hay Copper.
    • Ambient Temp (Max. / Min. / Year / day): 40/-25/20/30oC (C2)..
    • Altitude: ≤ 1000 m
    • Environmental class: E2
    • Fire resistance class:F1
    • Climate category: C2
  • LBS Treo tru

    Load Break Switch (LBS)

    1.Rated voltage: 24kV -36kV

    2.Rated power-frequency withstand voltage 50Hz 1Min (kV r.m.s.):

    – To earth and between phase: 50 / 70 kV

    – Across the isolating distance: 60 /80 kV

    3.Rated lightning impulse withstand voltage (peak value):

    – To earth and between phase: 125 / 170 kV

    – Across the isolating distance: 145 /195 kV

    4.Rated current: 630A

    5.Short-time withstand current: 20kA/3s

    6.Peak value: 50kA

    7.Breaking capacity:

    • Mainly active load: 630A
    • Closed-loop circuits: 630A
    • Line-charging breaking current: 50A
    • Cables-charging breaking current: 50A
    • No load transformer: 6.3A

    8. Protection degree: IP67

    9. Altitude: <= 1000m

    10. Ambient temperature: -40 to 60 °C

  • AN01813_Cover_2.indd

    Measuring Devices and Power Management

    Measuring Devices and Power Monitoring: 

    • Standard: IEC 61557 , IEC 60255
    • Rated operational voltage Ue: 230V AC
    • Values: U,I,S,P,Q,LF…
    • 5TE6 REG socket outlets up to 16 A
  • AN01813_Cover_2.indd

    Miniature Circuit Breakers – MCB

    MCB

    • Standards: IEC/EN 60898 , EN 60947-2
    • Rated current in up to 125A
    • Rated voltage Un: 230/400V AC
    • Icu up to 15kA
    • Functions: Overloads and Short-circuits protection
    • Additional components can be retrofitted individually
  • AN01813_Cover_2.indd

    Molded Case Circuit Breakers – MCCB

    MCCB-3VT

    • Standard: IEC/EN 60947-2
    • Rated current in up to 1600A
    • Rated operational voltage Ue: 690V
    • Rated ultimate short-circuit breaking capacity at 415 V up to 65 kA

    MCCB-SENTRON 3VL

    • Standard: IEC/EN 60947-1 , IEC/EN 60947-2 , DIN VDE 0660-100&101
    • Rated current in up to 1600A
    • Rated operational voltage U: 415/440/690V AC
    • Rated ultimate short-circuit breaking capacity up to 100 kA
    • Mounting type: Fixed, withdrawable, plug-in
    • Comunication intergrated
  • AN01813_Cover_2.indd

    Monitoring Devices

    Monitoring Devices:

    • Standard: IEC 60947 , IEC 60255
    • Transfer switches
    • Monitoring devices for electrical values
    • Monitoring devices for plants and devices
    • Charging infrastructure for electric vehicles
  • AN01813_Cover_2.indd

    Overvoltage Protection Devices

    Lightning arresters: Overvoltage Protection Devices

    • Standard: IEC 61643-11
    • Rated voltage Un: 240/415V AC
    • Lightning impulse current up to: 75/100 kA
    • Protection level up to: 5kV
  • Image converted using ifftoany

    Power Xpert UX

    • Up to 24kV, 36 kV, 25 kA/3s, 2500 A busbar, 2500 A feeder
    • Impulse withstand voltage: 125kV
    • Power frequency withstand voltage: 50kV
    • Rated frequency: 50/60 Hz.
    • Metal-Clad design.
    • Single-busbar System
    • Air-insulated and Solid insulated system
    • Rated short-time withstands current, 25kA/ 3s, 31.5kA/3s
    • Internal arc classification AFLR up to 31.5kA
    • Degree of protection: IP4X (IP41, IP42 or IP44 as an option)
    • Loss of service continuity category: LSC2B
    • Partition class: PM
    • Standard color: RAL 7035
    • Rack-in, rack-out operations of the circuit-breaker truck with the high-voltage door closed.
    • Factory-assembled, type-tested switchgear according to IEC 62 271-200.
    • Interlocking between high-voltage door and switching device.

     

  • Xgis

    Power Xpert XGIS

    • Rate voltage: 36/38 kV
    • Rated lightning impulse withstand voltage : 170 kV
    • Rated short-duration power-frequency withstand voltage: 80 kV
    • Rated frequency: 50/60 Hz
    • Internal arc class: IAC -AFLR
    • LSC: LSC2B
    • Earthing circuit: 31.5kV/3s
    • Busbar: 1250A, 2000A
    • Rated normal current for circuit-breaker feeders: 1250A, 2000A
    • Rated short-time withstand current: 31.5kA/3s
    • Rated short-circuit breaking current: 31.5kA
    • Rated peak withstand current: 82kA
    • Number of short-circuit breaking operations: 30 times
    • IP: 65
    • Gas-insulated
    • Hermetically enclosed
    • Factory-assembled, type-tested switchgear according IEC 62 271-200